230 x 75 mm vent, with decorative 11mm x 11mm crimped brass wire mesh, Hi flow static vents. They give 5,100 Sq mm of ventilation per vent.
The Australian Building code 3.4.1 deals with sub-floor ventilation. There are 3 climate zones, Zone 1 is central Australia and requires 2,000 sqmm of ventilation per linear metre of external wall, using Aleta 230 x 75 vents in Zone 1 would mean spacings at 2.6 metres. Zone 2 is in land Australia and requires 4,000 sqmm of ventilation per linear metre of external wall, using Aleta 230 x 75 vents in Zone 2 would mean spacings at 1.3 metres. Zone 3 is coastal Australia and requires 6,000 sqmm of ventilation per linear metre of external wall, using Aleta 230 x 75 vents in Zone 3 would mean spacings at .85 metres.
It should be noted that extra ventilation may be required if : excessively damp sub-floor or if all walls can't be ventilated.
Vents should be placed no more than 600mm from corners and evenly spaced around the building.
203 Dark Brown Vent 230x75 Brass Wire
- Product Code: 203 Dark Brown Vent 230x75 Brass Wire
- Availability: In Stock
-
$15.00